Adit 3200USER MANUALPart Number: 770-0156 BAProduct Release: 1.6September 2007
x Adit 3200 - Release 1.6PrefaceWarrantyTHE WARRANTIES IN THIS AGREEMENT REPLACE ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, AND ALL OTHER OBLIGATIONS
TABLE OF CONTENTSPrefaceCompliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
xii Adit 3200 - Release 1.6Table of ContentsCompliant Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CHAPTER 1Adit 3200 Base PlatformIn this Chapter Overview Technical Specifications Chassis
1-2 Adit 3200 - Release 1.6Adit 3200 Base PlatformOverviewOverviewThe Adit 3200 series IP Business Router is a new breed of access equipment designed
Adit 3200 - Release 1.6 1-3 Adit 3200 Base PlatformTechnical SpecificationsTechnical SpecificationsComponents Included Accessories- Wall mount brack
1-4 Adit 3200 - Release 1.6Adit 3200 Base PlatformTechnical SpecificationsVPN IPSec tunneling and PPTP & L2TP support DES, 3DES and AES IKE-bas
Adit 3200 - Release 1.6 1-5 Adit 3200 Base PlatformTechnical SpecificationsRegulatory ApprovalsUSA UL60950 FCC Part 15, Class A FCC Part 68Canada
1-6 Adit 3200 - Release 1.6Adit 3200 Base PlatformChassisChassis(1) 10/100Base-TEthernet (WAN)(4) 10/100Base-TEthernet (LAN) AlarmStatusReset RS-232Ma
CHAPTER 2Physical InstallationIn this Chapter Unpacking and Inspection Installation Environment Compliant Installation Wall Mounting Rack Mount
Copyright 2007 Carrier Access Corporation. All rights reserved.The information presented in this manual is subject to change without notice and does n
2-2 Adit 3200 - Release 1.6Physical InstallationUnpacking and InspectionUnpacking and InspectionWARNING! OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTA
Adit 3200 - Release 1.6 2-3 Physical InstallationUser SafetyUser SafetyCAUTION! WHEN USING YOUR TELEPHONE EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD
2-4 Adit 3200 - Release 1.6Physical InstallationCompliant InstallationNOTE: It is important the DS1/E1 Network Interface Cables are secured separatel
Adit 3200 - Release 1.6 2-5 Physical InstallationWall MountingWall MountingBefore beginning the mounting process, verify that the installation area is
2-6 Adit 3200 - Release 1.6Physical InstallationRack MountingRack MountingNOTE: Rack mounting kits are available for both 19 and 23 inch racks. 1 Rac
Adit 3200 - Release 1.6 2-7 Physical InstallationRack Mounting4. Place the Adit on the Tray Slide and attach with 4 screws removed in step 2. 5. Slide
2-8 Adit 3200 - Release 1.6Physical InstallationAdit 3104, 3200, 3300 and 3400 Battery BackupAdit 3104, 3200, 3300 and 3400 Battery Backup The Adit 31
CHAPTER 3Electrical Installation & CablingIn this Chapter Adit 3200 Interface Connectors Reset Button Alarm/Status LEDs
3-2 Adit 3200 - Release 1.6Electrical Installation & CablingAdit 3200Adit 3200ConnectionsThe following illustrations show all connectors on the Ad
Adit 3200 - Release 1.6 3-3 Electrical Installation & CablingInterface ConnectorsInterface ConnectorsThe following are the Adit 3200 interface co
PREFACEPrefaceComplianceSafety of Information Technology EquipmentThe Adit 3200 is safety certified by Underwriters Laboratories and is compliant with
3-4 Adit 3200 - Release 1.6Electrical Installation & CablingInterface ConnectorsPower The Adit 3000 is powered by a limited -48 VDC Power source.
Adit 3200 - Release 1.6 3-5 Electrical Installation & CablingInterface ConnectorsRS-232 Craft Port (Female DB-9)The RS-232 craft port connector (
3-6 Adit 3200 - Release 1.6Electrical Installation & CablingInterface ConnectorsDS1/E1 Connection PortsEach DS1/E1 connection port is equipped wit
Adit 3200 - Release 1.6 3-7 Electrical Installation & CablingInterface Connectors10/100Base-TX Ethernet The 10/100Base-TX Ethernet (female) ports
3-8 Adit 3200 - Release 1.6Electrical Installation & CablingReset ButtonReset ButtonThe system can be reset by pressing the reset button located o
CHAPTER 4ConfigurationAfter the Adit 3200 is installed (see Compliant Installation on page 2-3), the system can now be provisioned.In this Chapter PC
4-2 Adit 3200 - Release 1.6ConfigurationPC Network ConfigurationPC Network ConfigurationWhen a PC is connected directly or indirectly to the Adit 3200
Adit 3200 - Release 1.6 4-3 ConfigurationPC Network ConfigurationLinux1. Login into the system as a super-user, by entering su at the prompt.2. Type
4-4 Adit 3200 - Release 1.6ConfigurationWeb-Based ManagementWeb-Based ManagementThe web-based management interface allows you to control various syste
Adit 3200 - Release 1.6 4-5 ConfigurationSetting up a CLI ConnectionSetting up a CLI ConnectionA CLI connection will require the LAN or WAN IP addres
iv Adit 3200 - Release 1.6PrefaceComplianceThe Facility Interface Code (FIC) associated with each private line application represents the type of serv
4-6 Adit 3200 - Release 1.6ConfigurationLog inLog inAfter successful connection, via telnet or HyperTerm, the user must login. Default Logins are:Logi
Adit 3200 - Release 1.6 4-7 ConfigurationKey Enabled Software FeaturesKey Enabled Software FeaturesThe Adit 3200 has additional features that are not
4-8 Adit 3200 - Release 1.6ConfigurationBasic ConfigurationBasic ConfigurationThe following configuration is divided into logical sections, where each
Adit 3200 - Release 1.6 4-9 ConfigurationBasic ConfigurationRestore Factory DefaultsIf the unit is not out-of-the-box, you may want to verify that th
4-10 Adit 3200 - Release 1.6ConfigurationBasic ConfigurationModify Default Admin UserFor security purposes it is recommended that the Administrator Us
Adit 3200 - Release 1.6 4-11 ConfigurationBasic ConfigurationModify the User information, and select OK to save. It is important to note that you ne
4-12 Adit 3200 - Release 1.6ConfigurationBasic ConfigurationConfigure Ethernet WAN InterfaceIn the web-browser:1. Select Network Connections from the
Adit 3200 - Release 1.6 4-13 ConfigurationBasic Configuration6. Set Internet Protocol to Obtain an IP Address Automatically, from the pulldown menu.
4-14 Adit 3200 - Release 1.6ConfigurationBasic ConfigurationConfigure Serial 1 as WANIn the web-browser:1. Select Network Connections from the Navigat
GLOSSARYAMI Automatic Mark InversionARP Address Resolution ProtocolB8ZS Bipolar with 8 Zero SubstitutionBIT Binary DigitBPS Bits Per SecondBPV Bipolar
Adit 3200 - Release 1.6 vPrefaceComplianceIndustry Canada ICES-003EnglishThis class A digital apparatus complies with Canadian ICES-003.FrenchCet appa
Glossary-2 Adit 3200 - Release 1.6GlossaryDLCIDLCI Data Link Connection IdentifierDMZ Demilitarized ZoneDNS Domain Naming SystemDS0 Digital Signal Lev
Adit 3200 - Release 1.6 Glossary-3 GlossaryNATNAT Network Address TranslationNCS Network-based Call SignalingNEBS Network Equipment Building Standard
Glossary-4 Adit 3200 - Release 1.6GlossaryWANWAN Wide Area NetworkWINS Windows Internet Naming Service
Adit 3200 - Release 1.6 Glossary-5 Glossary10Base-T10Base-T The most widely installed Ethernet local area networks (LANs) use ordinary telephone twis
Glossary-6 Adit 3200 - Release 1.6Glossarychannelchannel A generic term for a communications path on a given medium; multiplexing techniques allow pro
Adit 3200 - Release 1.6 Glossary-7 GlossaryElectro-magnetic Interference (EMI)Electro-magnetic Interference (EMI)Equipment used in high speed data sy
Glossary-8 Adit 3200 - Release 1.6Glossarygatewaygateway An entrance and exit into a communications networkGraphical User Interface (GUI)GUI, pronounc
Adit 3200 - Release 1.6 Glossary-9 GlossaryLocal Area Network (LAN)Local Area Network (LAN)A short distance data communications network (typically wi
Glossary-10 Adit 3200 - Release 1.6Glossarymodemmodem MOdulator-DEModulator, a device that takes digital computer signal, converts it to analog, and s
Adit 3200 - Release 1.6 Glossary-11 GlossaryPPPPPP Point-to-Point Protocol. is used for establishing a point-to-point link that provides a single, pr
vi Adit 3200 - Release 1.6PrefaceSafety InformationSafety InformationCAUTION! ALWAYS USE CAUTION WHEN INSTALLING TELEPHONE LINES. READ THE CAUTIONS
Glossary-12 Adit 3200 - Release 1.6GlossarySAPSAP Service Access Point. signal A generated electrical impulse that is a change in voltage to trigger a
Adit 3200 - Release 1.6 Glossary-13 GlossaryWide Area Network (WAN)Wide Area Network (WAN)A private long distance network that uses leased lines to c
Glossary-14 Adit 3200 - Release 1.6GlossaryVirtual Local Area Network (VLAN)
INDEXNumerics100Base-T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3AAC Power (Adapter) . . . . . . . . . . . . . . . .
Index - 2 Adit 3200 - Release 1.6IndexNNnon-operating altitude . . . . . . . . . . . . . . . . . . . . . . . . . 2-2Ooperatingaltitude . . . . . . .
Adit 3200 - Release 1.6 viiPrefaceElectrostatic Discharge (ESD) PrecautionsElectrostatic Discharge (ESD) PrecautionsESD can damage processors, circuit
viii Adit 3200 - Release 1.6PrefaceWarrantyWarrantyCarrier Access warrants to BUYER that Product Hardware will be free from substantial defect in mate
Adit 3200 - Release 1.6 ixPrefaceWarrantySeverity 2 issues are failures of the Licensed Software to comply with the Carrier Access software specificat
Kommentare zu diesen Handbüchern